Repository logo
 

Analysis of a pilot-scale anaerobic baffled reactor treating domestic wastewater.

dc.contributor.advisorBuckley, Christopher Andrew.
dc.contributor.authorFoxon, Katherine Maria.
dc.date.created2009
dc.date.issued2009
dc.descriptionThesis (Ph.D.)-University of KwaZulu-Natal, Durban, 2009.en_US
dc.description.abstractThis thesis presents a chemical, microbiological and mathematical analysis of an anaerobic baffled reactor (ABR) treating domestic wastewater. The purpose of this study was to gain an understanding of the mechanisms of treatment of domestic wastewater in an ABR at pilot-scale, and to use this understanding to develop some guidelines for the design of ABR technology for the anaerobic treatment or pre-treatment of domestic wastewater. Previous research has been undertaken on ABR technology, but no detailed studies of the performance of an ABR on domestic wastewater at pilot-scale have been reported. In this thesis, operating data from a 3 000 ℓ pilot-scale ABR are presented and analysed. Two hypotheses were proposed: that (i) the baffled design of the reactor would facilitate phase separation whereby acidogenic and methanogenic processes predominate in different physical locations in the reactor; and (ii) the critical design parameter is the applied hydraulic retention time. The principle findings of this research were: • The pilot-scale ABR functioned as a solids retention device. Particulate material was retained through settling in the first compartment, forming a gel-like matrix. Reduction of solids occurred through anaerobic conversion to CH4 and CO2. • Partial phase separation of acidogenic and methanogenic communities was observed. • The major factor that controlled biomass washout rate and therefore reactor performance was upflow velocity in each compartment. At higher upflow velocities, slow growing microorganisms failed to establish, resulting in increased solids accumulation rates, while at lower upflow velocities, stable digestion proceeded. • Relatively poor treatment rates were obtained due to the low inherent alkalinity of waters in eThekwini municipality resulting in low operating pH values. • Insufficient pathogen reduction was observed indicating that post-treatment of effluent would be required. It was concluded that the benefit of the baffled design was related to the system’s solids retention characteristics and that the critical design parameters for an ABR domestic wastewater treatment unit were compartment upflow velocity and applied hydraulic retention time.
dc.identifier.urihttp://hdl.handle.net/10413/403
dc.language.isoenen_US
dc.subjectSewage--Purification--Anaerobic treatment.en_US
dc.subjectTheses--Chemical engineering.en_US
dc.titleAnalysis of a pilot-scale anaerobic baffled reactor treating domestic wastewater.en_US
dc.typeThesisen_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Foxon_Katherine_M_2009.pdf
Size:
18.24 MB
Format:
Adobe Portable Document Format
Description:
Thesis
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.86 KB
Format:
Item-specific license agreed upon to submission
Description: