    Safety implications of the introduction of a specially tested assembly into the South African national standard for low-voltage assemblies.

    Thumbnail
    View/Open
    Thesis. (2.375Mb)
    Date
    2004
    Author
    Bonner, Mark James.
    Metadata
    Show full item record
    Abstract
    Low-voltage switchgear and controlgear assemblies with a rated short-circuit withstand strength above 10 kA, are required, by law, to conform to the South African standard, SANS 1473-1 (Low Voltage Switchgear and Controlgear Assemblies: Part 1: Typetested, partially type-tested and specially tested assemblies with rated short-circuit withstand strength above lOkA). Standard SANS 1473-1 stipulates three categories of assemblies i.e. type-tested, partially type-tested and specially tested assemblies. The specially tested assembly is unique to the South African market, while the other two categories are stipulated in standard SANS IEC 60439-1 (Low Voltage Switchgear and Controlgear Assemblies: Part 1: Type-tested and partially type-tested assemblies), which is internationally accepted in many countries as the applicable low-voltage assembly standard. Standard SANS 1473-1 specifies seven type-tests for certification as a type-tested assembly (TTA), but specifies, at most, three type-tests for certification as a specially tested assembly (STA). The underlying purpose of a technical standard is to provide for the safety of people and property, with the purpose of the research being twofold: 1. To investigate if the testing requirements specified for a specially tested assembly (STA), in accordance with standard SANS 1473-1, are correctly applied, and do not pose any safety risks. 2. To investigate any safety risks that stem from the fact that four type-tests are excluded for verification as a specially tested assembly (STA), as opposed to the seven type tests required for verification as a type-tested assembly (TTA). The document highlights the technical inadequacies of an assembly that is certified as a STA, in accordance with standard SANS 1473-1, and the potential safety risks associated with this type of assembly classification.
    URI
    http://hdl.handle.net/10413/4201
    Collections
    • Masters Degrees (Electrical Engineering) [182]

    DSpace software copyright © 2002-2013  Duraspace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of ResearchSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsAdvisorsTypeThis CollectionBy Issue DateAuthorsTitlesSubjectsAdvisorsType

    My Account

    LoginRegister

    DSpace software copyright © 2002-2013  Duraspace
    Contact Us | Send Feedback
    Theme by 
    @mire NV